Operation rules for refrigerators to standardize daily operation
Author:Engineer - Bigeyes date:2019-11-05 Origin:cold room projects
Operation rules for refrigerators to standardize daily operation

Operation rules for refrigerators to standardize daily operation

1.In order to prevent the freezing and thawing cycle from damaging the cold storage structure, the external buildings of the cold storage shall not be changed at will according to the scope of use and use requirements specified in the design (Yangtzecooling cold storage shall consider the needs of the situation, produce the easy to install cold storage board, customize the assembled cold storage, and reassemble according to the special needs)

2.Water vapor shall be prevented from permeating into the thermal insulation layer. The walls, floors, roof and door frames of the cold storage shall be free of water, ice and frost. It shall be checked regularly, cleaned and recorded at any time when it is found.

3.The space between shelves in the cold storage shall meet the requirements, so that frozen goods can be placed safely and firmly, which is convenient for operators to check and count. There is a certain scientific proportion in the placement of frozen products, the height of evaporator on the top of the wall and the width of the channel for the frozen products that are frequently in and out.

4.In order to prevent the floor from freezing damage and damage, in the design of the floor of the cold storage, the budget can bear certain load, and it is paved with damp proof and heat insulation layer. If it is necessary to carry goods in and out by forklift, it is also necessary to add a bearing layer on the heat insulation layer. If the protective layer of the floor surface is damaged and the moisture flows into the thermal insulation layer, the thermal insulation effect will be affected and the service life of the reservoir will be reduced.

5.The cold storage door is the most frequently used and used part, which should be checked frequently. If the cold storage door is found to be deformed, the door lock is out of order, the sealing strip is damaged, and the electric heating wire is damaged, it needs to be repaired or replaced in time to prevent safety accidents.

6.When removing the frost from the aluminum in the cold storage, it is not allowed to use the steel parts to knock the exhaust pipe at will, which will damage the aluminum exhaust and affect the refrigeration efficiency.

FAQ of cold room

Yangtzecooling Goals

Customize your cold room project.

Excellent cold room panel production process

  • High quality polyurethane material foaming
    Polyurethane Materials

    High quality polyurethane material foaming

  • 20000 square meters cold room panel monthly
    Several production lines

    20000 square meters cold room panel monthly

  • Cold room design according to your needs
    Cold room design

    Cold room design according to your needs

  • Professional cold room installation
    Professional installation team

    Install a durable cold room for you